Carrello 0

RWA RWZ 4-8d 230V 50Hz Control Unit For Smoke And Heat Ventilation Systems For Use With RWA Chain Actuators Topp

Topp
Brands: Topp
Code: 8C0041
-15%
€ 983,45 € 1.157,00
Prices excluding VAT
Are you looking for an actuator from the Topp catalog that is not on our site? Contact us and ask for a quote.

- +

RWA RWZ 4-8d 230V 50Hz control unit for smoke and heat ventilation systems for use with RWA chain actuators Topp

Applications of the RWA RWZ 4-8d control unit

For smoke and heat evacuation systems.
It can be used with RWA Actuators and RWA Detectors (available separately on Windowo).

 

RWA RWZ 4-8d control unit for smoke and heat evacuation systems Topp

  • Output for connecting 24V actuators;
  • VdS approval according to the directive VdS 2581 and VdS 2593;
  • Internal power supply certified according to DIN EN 12101-10;
  • Control element certified according to prEN 12101-9.
 

3 signal lines

  • Automatic fire detector;
  • RT 2 alarm button to display alarm, fault and reset button;
  • Fire detection panel or other automatic fire detector.
 

Alarm functions

Reset of the alarm using the RT2 button or control unit.
Selectable functions:
  1. " Auto-Closed " (automatic closing after alarm reset);
  2. " Fault = alarm " (alarm in case of failure of a signal line);
  3. " Automatism deactivated " (automatic start commands - except alarm - are deactivated);
  4. " Thermal alarm " (exceeding an internal box temperature of 70 ° C).
 
  • Possibility of connection for ventilation button;
  • Adjustable aeration position and duration;
  • Possibility of connecting a wind and rain control;
  • Operation, alarm and fault displays on the emergency button;
  • Internal service display for detailed status indication for installation and maintenance;
  • Insertable clamps (except actuator output);
  • When the travel direction is switched directly, the actuators are briefly stopped before the change in direction;
  • Box in bright gray sheet steel (RAL 7035).
 

Technical features of the RWA RWZ 4-8d control unit

  • Supply voltage: 230V 50Hz;
  • Output voltage: 24v;
  • Maximum absorbed current: 1,1A;
  • Output current: 8A;
  • Backup battery: 2 x 7Ah / 12V;
  • Type of service: S1 - continuous;
  • Predispositions: wind, rain sensor and manual controls;
  • Operating temperature: - 5°C + 40°C;
  • Dimensions (mm): 400 x 400 x 135.
 

Number of connectable actuators

  • C160 RWA c.360: 19;
  • C160 RWA c.600: 13;
  • C160 RWA c.360 tandem: 9;
  • ACK4 RWA: 4;
  • ACK4S RWA: 6.
RWA actuators are available separately on Windowo.

Products that might interest you

Recently viewed products

Newsletter

Seguici

© Windowo All rights reserved - VAT: 02324570221 Software Ecommerce by Daisuke ®